Box loading machine maintenance:
1) Lubricate all transmission components inside the equipment every week and do not add too much oil to avoid contaminating the materials. Adjust each conveyor belt every week to ensure that the conveyor belt does not deviate.
2) When operating equipment, remind each other to prevent personnel and equipment from mishandling accidents.
3) When cleaning the equipment, it is strictly prohibited for water to enter the electrical parts to avoid electric shock accidents and equipment accidents.
4) When operating the touch screen, be careful and use your hands to avoid damage. Do not use other objects as a substitute for manual operation.
5) Weekly inspection of the screws and transmission components of the equipment connection components for looseness, and inspection of the material warehouse transmission chain ring for detachment.
6) During the operation of the machine, attention should be paid to whether there is any abnormal noise or odor, and it should be quickly shut down and reported for repair.
Box loading machine maintenance:
1) When repairing the packaging machine equipment, the power must be cut off, the compressed air must be turned off, and maintenance can only be carried out after confirming that there are no errors.
2) Check all transmission components weekly to ensure they are not loose or abnormal.
3) Add lubricating oil to all transmission components in the chassis every week to ensure flexible and normal transmission of each component. Add lubricating grease to the spindle and cam transmission components.
4) Every month, use compressed air to dust the electrical control box, tighten all wiring terminals, wipe the equipment and electrical surface with a dry towel, and wipe the interior of the equipment chassis with cotton thread to ensure that the equipment surface is free of visible dust and dirt, and the equipment presents a true color.
5) Check the switch button and emergency stop button every month to ensure their normal and effective operation.
6) Change the lubricating oil every 5000 hours, and the reducer specification is hyperbolic gear oil.